<style type="text/css"> .wpb_animate_when_almost_visible { opacity: 1; }</style> PJM Grid Operator: We Can Handle 30 Percent Renewable Energy Integration, And Here's How - Open Road Renewables

Experts believe that the PJM Interconnection system, which encompasses all or parts of Delaware, Illinois, Indiana, Kentucky, Maryland, Michigan, New Jersey, North Carolina, Ohio, Pennsylvania, Tennessee, Virginia, West Virginia and the District of Columbia, can handle up to 30 percent of its energy from wind and solar without “any significant reliability issues,” assuming transmission upgrades and additional regulation reserves — and at the same time reducing costs and reliance on its costlier conventional generation fleet.

Twelve PJM member states have renewable portfolio standards ranging from 18-25 percent, most with solar carve-outs. PJM projects its own wind and solar requirements will continue to steadily build from roughly 4 GW combined wind and solar in 2010 to 33 GW of wind and over 9 GW of solar by 2029. [Update: PJM’s latest Regional Transmission Expansion Plan suggests it’ll need to accommodate roughly 38 GW of renewables to meet all those states’ RPS targets by 2028.] To get their arms around this rapidly increasing amount of wind and solar energy in its infrastructure back in the spring of 2011 PJM stakeholders requested a study, led by GE Energy, to assess the operational, planning, and market impacts of adding large-scale integration of wind and solar power over the next 15 years. The study covered how it would take shape and be operated, what transmission upgrades would be required, capacity values, and general overall impact on PJM operations. Ten scenarios were explored, from simply maintaining 2011 levels of 2 percent renewable integration, to meeting a 14 percent RPS mandate by 2026, up to a maximum of 30 percent energy annually from solar and wind.

Preliminary results were disclosed last fall, and final results were presented last week. The bottom line: PJM says its system “would not have any significant reliability issues operating with up to 30 percent of its energy [from renewables]” (note: that’s energy, not capacity) though it will require significant additional transmission (nearly $14 billion) and regulation reserves (up to 1.5 GW).

Here’s a shortlist of the findings, which are summarized here and discussed in more detail here and here:

  • While suggesting that independent system operators (ISOs) and regional transmission organizations (RTOs) are better suited to handle integration, PJM acknowledges its big footprint would “greatly reduce” variability-related challenges, such as weather diversity and power forecasting/scheduling.
  • Every scenario they explored would reduce PJM’s fuel costs and variable operation/maintenance costs, and lowered average locational marginal prices.
  • Top-end 30 percent renewables integration would mean more cycling on PJM’s existing generation fleet and would lower coal and combined-cycle generation under all scenarios. Renewables’ lower capacity factors would result in lower revenues for conventional generation resources, but “these increased costs were small relative to the value of the fuel displacement.”
  • They also looked at energy storage and demand response, finding that 1 GW of storage or demand response used in place of generator resources for spinning reserves (in the 30 percent renewables scenario) reduced total system production costs by more than $17 million annually, or $1.99/MWh ($17.41/kW-year).